- This MPU6050 module with Triple Axis Accelerometer is based on MPU6050 chip from InvenSense. It sports a 3 Axis Accelerometer and 3 Axis Gyroscope along with an onboard Digital Motion Processor. The Digital Motion Processor is capable of processing complex 9 axis MotionFusion algorithms. The gyroscope is used to measure the rotational velocity or rate of change of angular position over time, along the X, Y and Z axis. The MPU6050 module with accelerometer uses the MEMS technology. The accelerometer measures acceleration over time. It can measure gravitational acceleration along 3 axis, using which we can calculate the angle at which sensor is positioned. So, by using, accelerometer and gyroscope data together, very accurate information on the position of the sensor can be obtained.
- Input Supply Voltage: 2.3V to 3.4V
- I2C digital output of 6 or 9 axis MotionFusion data in rotation matrix, quaternion, Euler Angle, or raw data format
- Tri-Axis angular rate sensor (gyro) with a sensitivity up to 131 LSBs/dps and a full-scale range of ±250, ±500, ±1000, and ±2000 °/sec (dps)
- Tri-Axis accelerometer with a programmable full scale range of ±2g, ±4g, ±8g and ±16g
- Embedded algorithms for run-time bias and compass calibration. No user intervention required.
“TTP223 1-Channel Capacitive Touch Sensor Module Red Color” has been added to your cart. View cart

MPU-6050 3-Axis Accelerometer and Gyro Sensor
- Chip built-in 16bit AD converter, 16-bit data output
- Driver Chip: MPU6050
- Operating Voltage: 3-5V DC
- Communication: I2C/IIC Protocol
- Gyro Range: ± 250, 500, 1000, 2000 °/s
- Accelerometer Range: ± 2 ± 4 ± 8 ± 16 g
₹500.00
Out of stock
Category:
Sensor
SKU: 1
Category: Sensor
Related products
-
Read moreUsage:-
- Soil moisture module is most sensitive to the ambient, generally used to detect the moisture content of the soil.
- When the module can not reach the threshold value, DO port output high, when the the soil humidity exceeds a set threshold value, the module D0 output low;
- The small board digital output D0 can be connected directly to the MCU, MCU to detect high and low, to detect soil moisture;
- Small board digital output DO can directly drive the buzzer module or relay module in our store, which can form a soil moisture alarm equipment;
- Small board analog output AO and AD module connected through the AD converter, you can get more precise values of soil moisture;
-
Read moreLDR Light Sensor Module LDR sensor module is used to detect the intensity of light. It is associated with both analog output pin and digital output pin labelled as AO and DO respectively on the board. When there is light, the resistance of LDR will become low according to the intensity of light. The greater…
-
Add to cart- Working Voltage:5V (DC)
- Static Current: Less than 2mA
- Output Signal:5V
- Sensor Angle: Less than 15 Degrees
- Detection Distance: 2 cm to 450 cm
- High Precision: Up to 2 mm
- Input Trigger Signal: 10µs TTL impulse
- Echo Signal: Output TTL PWL Signal
- High sensitivity ultrasonic range sensor
- Works with Arduino board
-
Add to cart- Supports momentary or latching/toggle modes.
- Supports Active High or Active Low output signal modes.
- Dimensions : 15mm x 11mm.
- Input Voltage : 2 Volt – 5.5 Volts DC.
- The response time max ~ 60mS in fast mode, ~220mS at low power mode @VDD=3V.
- Sensitivity can adjust by the capacitance(0~50pF).
- Have two kinds of sampling length by pad option(SLRFTB pin).
- Stable touching detection of the human body for replacing traditional direct switch key.
- Provides Fast mode and Low Power mode selection by pad option(LPMB pin).
- Provides direct mode、toggle mode by pad option(TOG pin).
- Open drain mode by bonding option, OPDO pin is open drain output, Q pin is CMOS output.
- All output modes can be selected active high or active low by pad option(AHLB pin).
- Have the maximum on time 100sec by pad option(MOTB pin).
- Have external power-on reset pin(RST pin).
- After power-on have about 0.5sec stable-time, during the time do not touch the keypad, and the function is disabled.
- Auto calibration.
- Re-calibration period is about 4.0 sec when the key has not be touched.
✕